Web Search: Goods Information jobs Download

        关于我们

        DGE Stage

         

        Features

        * Integrated Cover

        * Easy and Quick installation

        * Matched with AQM series motor and track

        * Excellent Cost-Performance

        * Linear motor positioning system

        * Modular Design System


        Specifications

          Unit AQM30-B1 AQM30-B2 AQM50-B1 AQM50-B2
        Continuous Force, Fc N 75.9 151.9 126.6 60
        Peak Force, Fp N 191.4 382.7 318.9 637.9
        Stroke (mm) mm 100-1200
        Resolution μm 0.1 / 0.5 / 1.0 / Analogue 1 Vpp
        Repeatability (1.0 μm) μm ±3.0
        Repeatability (0.5 μm) μm ±1.5
        Repeatability (0.1 μm) μm ±1.0
        Repeatability (Analogue) μm ±5
        Straightness (μm) μm ±3μm / 25 mm,NTE±5μm / 300 mm
        Flatness (μm) μm ±3μm / 25 mm,NTE±5μm / 300 mm
        Maximum Bearing Load (N) N 3944
        Recommended Row Moment (Nm) Nm 213
        Velocity (1.0 μm resolution) m/s

        12 m/s (20 μm scale pitch and 10 MHz counter frequency)

        Velocity (0.5 μm resolution) m/s 12 m/s (20 μm scale pitch and 10 MHz counter frequency)
        Velocity (0.1 μm resolution) m/s 4 m/s (20 μm scale pitch and 10 MHz counter frequency)

         Noted:

        ① The value depends on resolution.

        ② All measurement taken when module is mounted on a 5 μm flat granite table.

        ③ Using ABI51 encoder.

         

         Drawings